Market 02 · Advanced Therapy Manufacturing

Lot release that survives the audit.

Releasing an advanced-therapy lot means knowing what's in it: product identity, viral safety, process contaminants, construct verification. The wet-lab assays answer their part. The part that lives in the sequence — increasingly, with NGS in the dossier — demands measuring against a reference, with auditable criteria. That's this layer: deterministic sequence verification, zero false positives by construction, every verdict with its number and its signed receipt.

The panel

The panel: 929 entries, measured discrimination.

The ATMP index covers what a release dossier asks by sequence: process bacteria, compendial mycoplasma, the reference viruses (bovine serum, donor, cell line), and the complete human genome. In-panel organisms score 0.20 confidence (200/200 found); out-of-panel organisms sit at ~0.005 — a ~40× margin. The contamination screening runs in production today.

The panel on the platform

The mapping

The release criteria, mapped.

Against the practical QC guidance for ATMPs (Rangel-Martínez & Cruz-García, 2026), criterion by criterion:

Identity
0 false positives across 300,013 adversarial assays; sample identity 1.0 against the correct sample, ≤0.54 against any other.
Viral safety
reads classified against the reference viruses: 97.4% resolved to the exact source taxon (100% consistent at the common-ancestor level), on the frozen 500-read benchmark.
Construct verification
the binary verdict: MEMBER / RELATIVE / MUTATED / STRANGER. The match to the master construct as a criterion, not an impression.
Genomics
genotyping from reads, no aligner: 92.56% reproduced bit-identical on the full panel. The pre-screen before the expensive assay.
Documentary traceability
every verdict with a signed, publicly verifiable receipt: the digital audit trail of the dossier's sequence section.

The frontier

The honest frontier.

This layer does not replace the wet lab — sterility, endotoxin, potency, cell counts are not sequence questions, and we don't pretend they are. It is not a clinical dictum: it answers "what is in this sequence against which reference", not "what does this mean for a patient". Methods live today at the exploratory/qualified stages of the regulatory ladder (exploratory → qualified → validated), and the route to validation is part of the product. The frame we work within: EMA/CAT, EudraLex Vol. 4 Part IV, ICH Q5A(R2), FDA CMC, NOM-059-SSA1-2015, NOM-257-SSA1-2014, COFEPRIS.

Bring the lot.

Evaluations and custom panels start with a conversation.